| 16.0000 | 405.7800 | On-line detection of heavy metals and brominated flame retardants in technical polymers with laser-induced breakdown spectrometry | Michael Stepputat, Reinhard Noll | Plastic | Photomultiplier/Paschen-Runge Spectrometer/ | Link | 
                
                    
                        | 150.0000 | 405.7800 | Quantitative elemental determination in water and oil by laser induced breakdown spectroscopy | Pascal Fichet, Patrick Mauchien, Jean-François Wagne, Christophe Moulin | Liquids | Princeton Instruments ICCD Max/THR Monochromator/ | Link | 
                
                    
                        | 300.0000 | 405.7800 | Analysis of recycled thermoplasts from consumer electronics by laser-induced plasma spectroscopy | H. Fink, U. Panne , R. Niessner | Plastic | ESA 3000/ESA 3000/ | Link | 
                
                    
                        | 20.0000 | 405.7800 | Analysis of heavy metals in liquids using Laser Induced Breakdown Spectroscopy by liquid-to-solid matrix conversion | D.M. Diaz Pace, C. D’Angelo, D. Bertuccelli, G. Bertuccelli | Liquids | Photomultiplier/Monochromator/ | Link | 
                
                    
                        | 100.0000 | 405.7800 | Analysis of environmental lead contamination: comparison of LIBS field and laboratory instruments | R.T. Wainner, R.S. Harmon, A.W. Miziolek, K.L. McNesby, P.D. French | Lead | ADA Developed Portable System/ADA Developed Portable System/ | Link | 
                
                    
                        | 18.0000 | 208.8420 | Quantitative determination of wear metals in engine oils using LIBS: The use of paper substrates and a comparison between single- and double-pulse LIBS | Pavel Yaroshchyk, Richard J.S. Morrison, Doug Body, Bruce L. Chadwick | Oil | Oriel InstaSpec V/Oriel MS 257/ | Link | 
                
                    
                        | 300.0000 | 406.0000 | Pre-flight calibration and initial data processing for the ChemCam laser-induced breakdown spectroscopy instrument on the Mars Science Laboratory rover | D. Vaniman, R.L. Tokar, R. Perez, A. Ollila, H. Newsom, P-Y Meslin, N. Melikechi, J. Mazoyer, N. Lanza, O. Gasnault, Cecile Fabre, M.D. Dyar, D. Delapp, L. Deflores, A. Cousin, B.L. Barraclough, D. Blaney, S. Bender, S.M. Clegg, Ryan B. Anderson, O. Forni, J. Lasue, Sylvestre Maurice, Roger C. Wiens | Geological | ICCD/Czerny-Turner (Unspecified)/ | Link | 
                
                    
                        | 135.0000 | 405.8700 | Quantitative elemental determination in water and oil by laser induced breakdown spectroscopy | Pascal Fichet, Patrick Mauchien, Jean-François Wagne, Christophe Moulin | Oil | Princeton Instruments ICCD Max/THR Monochromator/Visual Basic | Link | 
                
                    
                        | 7.0000 | -10.0000 | Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument | Chunyi Liu, Xianglei Mao, Sudeep J. Pandey, Alexander A. Bol'shakov | Liquids | ICCD/Applied Spectra J200/Clarity | Link | 
                
                    
                        | 400.0000 | 405.7820 | Determination of Impurities in Uranium and Plutonium Dioxides by Laser-Induced Breakdown Spectroscopy | Christophe Moulin, Patrick Mauchien, Pascal Fichet | Nuclear | Princeton Instruments ICCD Max/Jobin Yvon HR1000/Winspec | Link | 
                
                    
                        | 4.1000 | 405.7800 | Analysis of lead and copper in soil samples by laser‑induced breakdown spectroscopy under external magnetic field | M.A. Baig, Rizwan Ahmed, Z A Umar, S. Mahmood, Nasar Ahmed, A. Jabbar, M. Akhtar | Soil | AvaSpec-2048-SPU/AvaSpec-2048-SPU/ | Link | 
                
                    
                        | 8000.0000 | 220.3500 | Detection of Metals in the Environment using a Portable Laser-Induced Breakdown Spectroscopy Instrument | Karen Y. Yamamoto, David A. Cremers, Monty J. Ferris, Leeann E. Foster | Soil | 6132/HR320/ | Link | 
                
                    
                        | 20.0000 | 405.7800 | Analysis of lead and sulfur in environmental samples by double pulse laser induced breakdown spectroscopy [Pb in Soil] | V.S. Burakov, M.I. Nedelko, V.A. Kononov, N.N. Vasilev, S.N. Isakov | Soil | LOTIS TII LIBS Instrument/LOTIS TII LIBS Instrument/ | Link | 
                
                    
                        | 3.0000 | 208.8420 | Quantitative determination of wear metals in engine oils using LIBS: The use of paper substrates and a comparison between single- and double-pulse LIBS | Pavel Yaroshchyk, Richard J.S. Morrison, Doug Body, Bruce L. Chadwick | Oil (double pulse) | Oriel InstaSpec V/Oriel MS 257/ | Link | 
                
                    
                        | 1.3000 | 405.8000 | Optimization of chemical and instrumental parameters in hydride generation laser-induced breakdown spectrometry for the determination of arsenic, antimony, lead and germanium in aqueous samples | Serife Yalcin, Semira Unal Yesiller | Liquids | Mechelle 5000/Andor iStar ICCD/ | Link | 
                
                    
                        | 0.1800 | 405.7000 | Detection of toxic elements using laser-induced breakdown spectroscopy in smokers’ and nonsmokers’ teeth and investigation of periodontal parameters | Yusuf B. Habibullah, Sami Shafik, M. Nasr, M.A. Gondal, Abdul M. Alhasmi | Biological | Andor ICCD/Andor Shamrock 500i/ | Link | 
                
                    
                        | 100.0000 | 405.7800 | Analysis of environmental lead contamination: comparison of LIBS field and laboratory instruments | R.T. Wainner, R.S. Harmon, A.W. Miziolek, K.L. McNesby, P.D. French | Lead | Princeton Instruments ICCD Max/Acton 300i/ | Link | 
                
                    
                        | 54.0000 | 283.3100 | Quantitative Analysis of Additives in Solid Zinc Alloys by Laser-induced Plasma Spectrometry | L. St-Onge , M. Sabsabi, Paulo Cielo | Zinc Alloys | IRY 700/McPherson 207/ | Link | 
                
                    
                        | 62.6000 | 405.7800 | Heavy Metals Detection in Zeolites Using the LIBS Method | P. Veis, Pavol Hudec, Michal Hornacek, Jozef Plavcan, Michaela Hornackova | Geological | Andor ICCD/Mechelle 5000/ | Link | 
                
                    
                        | 17.0000 | 405.8000 | Analysis of heavy metals in soils using laser-induced breakdown spectrometry combined with laser-induced fluorescence | Frank Hilbk-Kortenbruck, Reinhard Noll, Peter Wintjens, Heinz Falk, Christoph Becker | Soil | Photomultiplier/Spectrolab M/ | Link | 
                
                    
                        | 1.2700 | 405.7800 | Quantitative Determination of Manganese in Aqueous Solutions and Seawater by Laser-Induced Breakdown Spectroscopy (LIBS) Using Paper Substrates [Czerny Turner] | Junshan Xiu, Shilei Zhong, Huaming Hou, Yuan Lu, Ronger Zheng | Liquids | Acton Spectra Pro/Acton Spectra Pro/ | Link | 
                
                    
                        | 2.5000 | 405.8000 | Spectroscopic detection of health hazardous contaminants in lipstick using Laser Induced Breakdown Spectroscopy | M.A. Gondal, Z.S. Seddigi, M. Nasr, B. Gondal | Cosmetics | Ocean Optics LIBS2500+/Ocean Optics LIBS2500+/ | Link | 
                
                    
                        | 298.0000 | 405.7800 | Detection of Metals in the Environment using a Portable Laser-Induced Breakdown Spectroscopy Instrument | Karen Y. Yamamoto, David A. Cremers, Monty J. Ferris, Leeann E. Foster | Paint | 6132/HR320/ | Link | 
                
                    
                        | 22.0000 | 405.7900 | Rapid Lead (Pb) Analysis of Solder Plating on Semiconductor Leadframes | N/A | Semiconductor | RT100-B/RT100-B/ | Link | 
                
                    
                        | 547.0000 | 220.3530 | Preliminary studies of laser-induced breakdown spectrometry for the determination of Ba, Cd, Cr and Pb in toys | Quienly Godoi, Dário Santos Júnior, Lidiane Cristina Nunes, Flavio O. Leme, Iolanda Aparecida Rufini, Jose A.M. Agnelli, Lilian Cristina Trevizan, Francisco José Krug | Plastic | Kodak KAF 1001/ESA 3000/MATLAB | Link | 
                
                    
                        | 0.0740 | 405.7800 | Fast and sensitive trace metal analysis in aqueous solutions by laser-induced breakdown spectroscopy using wood slice substrates | Zhi-jiang Chen, Hong-kun Li, Ming Liu, Run-hua Li | Liquids | Hamamatsu CR114 Photomultiplier/Tianjin Tuopu WDS-5/ | Link | 
                
                    
                        | 4.5000 | 280.2000 | Determination of poisonous metals in wastewater collected from paint manufacturing plant using laser-induced breakdown spectroscopy | M.A. Gondal, T. Hussain | Liquids | LIBS2000+/LIBS2000+/ | Link |